Basic
₹1111/sqft
- 2D Floor Plans
- 3D Elevation
- Structural Drawings
- Working Drawings For Execution
Dalmia / Maha
Kamdhenu
- M 20 Grade for Column Footing, Plinth Beams, Staircase, Lintel and Columns.
- Slab Thickness – 5”
20 MM & 40 MM
M sand – Dry Wash
P sand – Fine Quality
6″ and 4″ Solid Blocks
For Column Footing is assumed to have a SBC of 180kN/m2 at 5’ Depth from EGL
3 Course of foundations for Outer walls
Finished Parking Floor Height – 1.5 ft From the Road Level
- 6″ Solid Blocks Work including fixing of Chicken Mesh and Smooth Plastering with Water Proofing
- Capacity: 1500ltrs for Built-up Area of 1000 Sft @ Rate ₹12/ltr)
Lintel is casted just above the Window Top & Door Top to distribute the load of the above Walls onto the walls below.
10 ft Height
Screed Concrete for terrace with appropriate water proof compound of average thickness 2” with 12mm downsize aggregates laid to slope of 1:80 towards rain water outlet.
By using Dr. Fixit
- Fixing of Doors Frames, Window Frames, Window Grills are included in the Package
- All materials including the wood grill clamp, bitumen for paint,
etc. are not included and must be provided by the Client
- Compound Wall Construction Upto 4 Ft Height @ ₹1300/Rft.
- Flagging Concrete for the set back Area @ ₹180/sft
10 Year Warranty on Structure
Cost of Front elevation will be charged extra as per the Architectural design
Standard
₹1250/sqft
- 2D Floor Plans
- 3D Elevation
- Structural Drawings
- Working Drawings For Execution
Zuari / Bharathi
Meenakashi or Turbo
- M 20 OPC Grade for Column Footing, Plinth Beams, Staircase, Lintel and Columns.
- Slab Thickness – 5”
20 MM & 40 MM
M sand – Dry Wash
P sand– Fine Quality
6″ and 4″ Compressed Blocks
For Column Footing is assumed to have a SBC of 180kN/m2 at 5’ Depth from EGL
3 Course of foundations for Outer walls
Finished Parking Floor Height – 1.8 ft From the Road Level
- 9″ Brick Work including fixing of Chicken Mesh and Smooth Plastering with Water Proofing
- Capacity: 1500ltrs for Built-up Area of 1000 Sft Rate @ ₹18/ltr
Lintel is casted just above the Window Top & Door Top to distribute the load of the above Walls onto the walls below.
10.5 ft Height
Screed Concrete for terrace with appropriate water proof compound of average thickness 2” with 12mm downsize aggregates laid to slope of 1:80 towards rain water outlet.
By using Dr. Fixit
- Fixing of Doors Frames, Window Frames, Window Grills are included in the Package
- All materials including the wood grill clamp, bitumen for paint,
etc. are not included and must be provided by the Client
- Compound Wall Construction Upto 4 Ft Height @ ₹1400/Rft.
- Flagging Concrete for the set back Area @ ₹200/sft
10 Year Warranty on Structure
Cost of Front elevation will be charged extra as per the Architectural design
Premium
₹1400/sqft
- 2D Floor Plans
- 3D Elevation
- Structural Drawings
- Working Drawings For Execution
ACC / Ramco
Indus or Prime Gold
- M 25 Grade for Column Footing, Plinth Beams, Staircase, Lintel and Columns.
- Slab Thickness – 6”
20 MM & 40 MM
M sand – Water Wash
P sand– Fine Quality
6″ and 4″ Hydraulic Pressed Blocks
For Column Footing is assumed to have a SBC of 180kN/m2 at 5’ Depth from EGL
3 Course of foundations for Outer walls
Finished Parking Floor Height – 1.8 ft From the Road Level
- RCC Sump with Smooth Plastering and Water Proofing
- Capacity: 1500ltrs for Built-up Area of 1000 Sft Rate @ ₹25/ltr
Lintel is casted just above the Window Top & Door Top to distribute the load of the above Walls onto the walls below.
10.5 ft Height
Screed Concrete for terrace with appropriate water proof compound of average thickness 2” with 12mm downsize aggregates laid to slope of 1:80 towards rain water outlet.
By using Fosroc Brush Bond
- Fixing of Doors Frames, Window Frames, Window Grills are included in the Package
- All materials including the wood grill clamp, bitumen for paint,
etc. are not included and must be provided by the Client
- Compound Wall Construction Upto 4 Ft Height @ ₹1500/Rft.
- Flagging Concrete for the set back Area @ ₹220/sft
10 Year Warranty on Structure
Cost of Front elevation will be charged extra as per the Architectural design
Premium+
₹1650/sqft
- 2D Floor Plans
- 3D Elevation
- Structural Drawings
- Working Drawings For Execution
Ultra- Tech
Tata or JSW
- M 25 OPC Grade for Column Footing, Plinth Beams, Staircase, Lintel and Columns.
- Slab Thickness – 6”
20 MM & 40 MM
M sand– Water Wash (Alpha / Thriveni)
P sand– Fine Quality
8″ and 6″ Hydraulic Pressed Blocks
For Column Footing is assumed to have a SBC of 180kN/m2 at 5’ Depth from EGL
3 Course of foundations for Outer walls
Finished Parking Floor Height – 1.8 ft From the Road Level
- RCC Sump with Smooth Plastering and Water Proofing
- Capacity: 1500ltrs for Built-up Area of 1000 Sft Rate @ ₹25/ltr)
Lintel is casted just above the Window Top & Door Top to distribute the load of the above Walls onto the walls below.
11 ft Height
Screed Concrete for terrace with appropriate water proof compound of average thickness 2” with 12mm downsize aggregates laid to slope of 1:80 towards rain water outlet.
By using Fosroc Brush Bond
- Fixing of Doors Frames, Window Frames, Window Grills are included in the Package
- All materials including the wood grill clamp, bitumen for paint,
etc. are not included and must be provided by the Client
- Compound Wall Construction Upto 4 Ft Height @ ₹1600/Rft.
- Flagging Concrete for the set back Area @ ₹220/sft
10 Year Warranty on Structure
Cost of Front elevation will be charged extra as per the Architectural design
Get In Touch
- 24/1, 1st Cross, Malleshwaram, Bengaluru 560003
- +919845742555